Fault Code | Possible Cause |
---|---|
9A | Incorrect HCM fitted |
9U | Problem with the code plug (faulty or not connected) |
B7 | Replace control board |
C6 | Running too fast / Running too slow |
C7 | Fan not running / Fan not running or airflow blocked |
D1 | Sensor wet or damaged (the boiler will block for 300 seconds before this condition) |
D1 | Sensor disconnected or damaged (the boiler will block for 300 seconds before this condition) |
D1 | Boiler overheat |
E2 | Flow sensor shorted or damaged |
E2 | Flow sensor disconnected or damaged |
E5 | Primary flow sensor overheated |
E9 | The main heat exchanger has overheated. Maximum temperature 105°C |
E9 | Maximum temperature sensor on the main heat exchanger has failed |
E9 | Maximum temperature sensor on the main heat exchanger has not been recognised |
E9 | Flue gas thermostat overheat |
EA | Failure of four ignition attempts. The boiler waits 30 seconds before another attempt is made |
EA | An established flame has been extinguished. This could be caused by: Moisture in the sump, due to a blocked sump/condensate trap, a strong wind into the flue |
EA | Gas valve coil disconnected |
EA | Flame not established during the first 4 seconds ignition period |
EA | There is an error where the pump is not detecting water – check pressure gauge and repressurise to 1 bar. |